Spectrophotometer

Atomic Absorption Spectrophotometer TRAS-601

Features :

Wavelength Range : 190 to 900 nm

Wavelength Accuracy : £ ±0.5 nm

Wavelength Repeatability : £ 0.3 nm (single direction)

Spectrum Bandwidth : 0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm

Resolution : <40%

Atomic Absorption Spectrophotometer TRAS-701

Features :

Wavelength range  : 190 to 900 nm

Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm

Accuracy of the wavelength : ±0.15 nm

Receptivity of the wavelength  : ≤0.04 nm

Baseline stability : ≤0.002A/30 min (Cu)

Double Beam UV VIS Spectrophotometer TRDUV-601

Features :

Spectrum Bandwidth : 2 nm

Wavelength Range : 190 to 1100 nm

Monochromatic Type : Czerny-Turner

Grating : 1600 lines/mm

Detector : Silicon Photocell

Double Beam UV VIS Spectrophotometer TRDUV-602

Features :

Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm

Wavelength Range : 190 to 1100 nm

Monochromatic Type : Czerny-Turner

Grating : 1600 lines/mm

Detector : Silicon Photocell

Double Beam UV VIS Spectrophotometer TRDUV-603

Features :

Monochromatic type : Czerny turner

Focal length : 160 mm

Wavelength Range : 190 to 1100 nm

Band Width : 1.8 nm

Wavelength Accuracy : ±0.3 nm

Double Beam UV VIS Spectrophotometer TRDUV-604

Features :

Monochromatic type : Czerny turner

Focal length : 160 mm

Wavelength Range : 190 to 1100nm

Band Width : 2 nm

Wavelength Accuracy : ±0.3 nm

Fluorescence Spectrophotometer TRFS-601

Features :

Exciting Optical Filters : Interface optical filter (10 nm bandwidth)

Wavelength : 365 nm

Emission Monochromatic : C-T diffraction grating (EM 200 to 900 nm )

Wavelength Accuracy : ±1 nm

Wavelength Repeatability : ≤0.5 nm

Micro-Spectrophotometer TRMS-601

Features :

Light Path : 1mm

sample Volume : 1 to 2μL

Detection Range : 190 to 850 nm

Wavelength Range : 190 to 1100 nm

Wavelength Accuracy : ± 1nm

Micro-spectrophotometer TRMS-602

Features :

Optical Path : 1/0.5/0.05 mm automatic conversion

Optical Range : 190 to 1100 nm

Sample Volume : 0.3 to 2.0 μl

Light Source : Long-life Xenon lamp

Detector : 3864 linear CCD array

Micro-spectrophotometer TRMS-603

Features :

Wavelength scanning Range : 190 to 850 nm

Wavelength Accuracy : ±1 nm

Optical Path : 1/0.5/0.05 mm automatic conversion

Optical Range : 190 to 1100 nm

Sample Volume : 0.3 to 2.0 μl

Micro Spectrophotometer TRMS-604

Features :

Wavelength Range : 190 to 850 nm

Wavelength Accuracy : ± 1 nm

Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)

Repeatability : <± 0.5 nm

Light Path : 1 mm, 0.05 mm (optical path automatic conversion)

Micro Spectrophotometer TRMS-605

Features :

Wavelength Range : 190 to 850 nm

Wavelength Accuracy : ± 1nm

Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)

Repeatability : <± 0.5 nm

Light Path : 1 mm, 0.05 mm (optical path automatic conversion)

Spectrophotometer TRNS-601

Features :

Wavelength Range : 900 to 1700 nm

Wavelength  Accuracy : ±1 nm

 Wavelength Reproducibility  : ≤1 nm

Wavelength Scanning Interval Absorbance : 1 nm, 4 nm, 8 nm, 16 nm

Reproducibility S/N : 0.002 A (at 0.4 A)

Single Beam UV VIS SpectrophotometerTRSUV-601

Features :

Photometry : Split Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS SpectrophotometerTRSUV-602

Features :

Photometry : Split Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS SpectrophotometerTRSUV-603

Features :

Photometry : Split Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS SpectrophotometerTRSUV-604

Features :

Photometry : Split Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS Spectrophotometer TRSUV-605

Features :

Photometry : Single Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS Spectrophotometer TRSUV-606

Features :

Photometry : Single Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS SpectrophotometerTRSUV-607

Features :

Photometry : Single Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Single Beam UV VIS SpectrophotometerTRSUV-608

Features :

Photometry : Single Beam

Monochromatic Type : Czerny-Turner

Focal Length : 160 mm

Grating : 1200 lines/mm

Detector : Silicon Photocell

Visible Spectrophotometer TRVS-601

Features :

Photometry : Single beam

Monochromatic Type : Littrow

Focal Length : 160 mm

Wavelength Setting : Manual Turn Knob

Wavelength Range : 325 to1000 nm

Energy Dispersion X-ray Fluorescence Spectrometer TRXS-601

Features :

Analysis Principle : Energy-dispersive X-ray fluorescence analysis

Element Measuring Range : Any element from Na(11)-U(92)

Minimum Measuring Limit : Cd/Hg/Br/Cr/Pb≤2 ppm

Sample Shape : Arbitrary size, any irregular shape

Sample Type : Plastic/metal/film/powder/liquid etc.